Technical data:
supply power | ~ 230 V |
controller | single-channel |
upper temperature range | + 60 °C |
bottom temperature range | - 29 °C |
cooperates with air conditioning systems | + |
single-pole relay | 16 A |
IP protection level | IP 20 |
installation | DIN rail |
width / height / depth | 52 / 90 / 60 mm |
Product details
Product details:
System control based on readings of the heated space temperature, air and ground temperature.
The device has a digital display for easy operating parameters setup and the current temperature reading from the sensor. The controller software allows you to set a single parameter called “trigger point” at the specified temperature range setting after selecting a level of the upper and lower temperatures.
The TVR 292 controller is equipped with a single-channel contactor and can directly attach circuits whose power output does not exceed 3500 W or indirectly by an additional voltage contactor.
The controller can be used to protect:
- roofs
- gutters
- downpipes
- drainage channels
- stairs
- sidewalks
- driveways and loading ramps
- wherever air temperature reading is enough to monitor the de-icing system
The controller operates with two types of sensors:
- CZP 200 - air sensor in the hermetic cover on the wall
- CZN 200 - cable sensor
The TVR 292 regulator cooperates with air conditioning. Adjusting the operating parameters of the device is the same as in the heating systems.
TVR 292 controller complies the European standard IEC 60800 1998