Technical data
Technical data:
supply power | ~ 230 V |
controller | single-channel |
upper temperature range | + 60 °C |
bottom temperature range | - 29 °C |
cooperates with air conditioning systems | + |
single-pole relay | 16 A |
IP protection level | IP 20 |
installation | DIN rail |
width / height / depth | 38 / 90 / 60 mm |
Product details
Product details:
System control based on readings of the heated space temperature, air and ground temperature.
The device has a digital display for easy operating parameters setup and the current temperature reading from the sensor. The controller software allows you to set a single parameter called “trigger point” at the specified temperature range setting after selecting a level of the upper and lower temperatures.
The TVR 290/291 controller is equipped with a single-channel contactor and can directly attach circuits whose power output does not exceed 3500 W, or indirectly by an additional voltage contactor.
The controller can be used to protect:
- roofs
- gutters
- downpipes
- drainage channels
- stairs
- sidewalks
- driveways and loading ramps
- wherever air temperature reading is enough to monitor the de-icing system
The controller operates with two types of sensors:
- TVR 290 version - with air wall sensor CZP 200
- TVR 291 version - with cable sensor CZN 200
The TVR 290/291 regulator cooperates with air conditioning. Adjusting the operating parameters of the device is the same as in the heating systems.
TVR 290/291 controller complies the European standard IEC 60800 1998